The plant model "Garage Door" represents the monitoring of a filling level. The interface module can be plugged onto the 40-pin "Interface" pin header on all "Trainingsboards".
With the respective program, a Level Monitoring can now be programmed and tested live. The filling level is performed manually.
The plant model "Garage Door" can be used with all "PLC4Training Trainingsboards".
Technical data:
Sensors/Inputs
2 SMD pushbuttons, connected with 2 inputs of the used PLC
request entry or exit
2 micro switches, connected with 2 inputs of the used PLC
end switch for garage door open or closed
Actuators/Outputs
2 LEDs to display the door movement, open or close
2 LED as traffic light on the entry and exit of the garage
Other
Power is supplied via the "Trainingsboard".
The "Garage Door" module can be operated with 12 to 24 volts.
The "Garage Door" module is plugged into the 40-pin "Interface" pin header of the "PLC4Training Trainingsboard".
Scope of delivery
Interface module - "Garage Door" (L x W x H) approx. 96 x 96 x 30 mm
Task description as PDF
Sample solution